/Help Center
End user

How to connect Omnitec door locks

Verified Nov 11, 20262 min read

With Omnitec connected, HotelBee sends the stay to your Omnitec lock server when you check a guest in, and the card is encoded on the reception encoder. For how locks fit into check-in, see Door lock integrations overview.

Before you start

  • Your Omnitec lock software set up by your installer, with rooms and common areas configured.
  • The address and port of the Omnitec lock server. HotelBee's servers connect to it over the internet, so it must be reachable from outside the hotel. Your installer or IT sets this up.
  • A card encoder at reception, and its reader number.
  • For passcodes or mobile keys: your Rent&Pass account details from Omnitec.

Connect the lock server

  1. Go to Settings → Integrations and click the button on the Omnitec Settings card.
  2. Enter Host / IP Address and Port.
  3. Enter Reader No, the encoder at reception, and User/Machine Name if your installer gave you one.
  4. Click Test connection and wait for Connection successful.
Empty Omnitec Settings connection fields

Choose the key type

  1. Pick the credential type: Physical Card, Passcode Only, Mobile Key Only, Card + Passcode or Card + Mobile Key.
  2. For any type with a passcode or mobile key, a Rent&Pass section appears. Fill in Client ID, Client Secret, Username, Password, API Base URL, Email Template and Passcode Length.
  3. Save with Active on, then click Test API.
Omnitec credential type set to Card + Passcode showing the Rent&Pass section

Common doors and rooms

  1. In Common Doors (Binary), enter the code from your installer: one digit per common area, 1 to open it, 0 to keep it closed.
  2. In Room Mapping, enter each room's Omnitec Room No as set up in your Omnitec software.
  3. Turn on Active and click Save.

What happens day to day

  • Check-in: HotelBee asks Omnitec for a card for the room, valid from the check-in time to the check-out time. Have a card on the reception encoder when you confirm check-in.
  • Room move or new dates while checked in: a new card is issued and the old one stops working.
  • Check-out: Omnitec cards stop working on their own at the end of the stay; HotelBee marks the key as ended.
  • With the Room keys step turned on, the check-in window shows Issued or Not issued with Retry.

Good to know

  • Saving needs the create or edit right on Settings. Retry needs the edit right on Reservations.
  • One card can open up to three rooms of the same reservation.
  • Mobile Key Only and Card + Mobile Key need the guest's email. Without it, a plain card is issued.
  • The mobile key email is sent by Omnitec, using the Email Template number.

Related articles